Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment

Open Access
Authors
  • E. Aprile
  • F. Agostini
  • M. Alfonsi
  • K. Arisaka
  • F. Arneodo
  • M. Auger
  • C. Balan
  • P. Barrow
  • L. Baudis
  • B. Bauermeister
  • A. Behrens
  • P. Beltrame
  • K. Bokeloh
  • A. Breskin
  • A. Brown
  • E. Brown
  • S. Bruenner
  • G. Bruno
  • R. Budnik
  • J.M.R. Cardoso
  • A.P. Colijn
  • H. Contreras
  • J.P. Cussonneau
  • M.P. Decowski
  • E. Duchovni
  • S. Fattori
  • A.D. Ferella
  • W. Fulgione
  • M. Garbini
  • C. Geis
  • L.W. Goetzke
  • C. Grignon
  • E. Gross
  • W. Hampel
  • R. Itay
  • F. Kaether
  • G. Kessler
  • A. Kish
  • H. Landsman
  • R.F. Lang
  • M. Le Calloch
  • D. Lellouch
  • L. Levinson
  • C. Levy
  • S. Lindemann
  • M. Lindner
  • J.A.M. Lopes
  • K. Lung
  • A. Lyashenko
  • S. MacMullin
  • T. Marrodán Undagoitia
  • J. Masbou
  • F.V. Massoli
  • D. Mayani Paras
  • A.J Melgarejo Fernandez
  • Y. Meng
  • M. Messina
  • B. Miguez
  • A. Molinario
  • G. Morana
  • M. Murra
  • J. Naganoma
  • U. Oberlack
  • S.E.A. Orrigo
  • E. Pantic
  • R. Persiani
  • F. Piastra
  • J. Pienaar
  • G. Plante
  • N. Priel
  • S. Reichard
  • C. Reuter
  • A. Rizzo
  • S. Rosendahl
  • J.M.F. dos Santos
  • G. Sartorelli
  • S. Schindler
  • J. Schreiner
  • M. Schumann
  • L. Scotto Lavina
  • M. Selvi
  • P. Shagin
  • H. Simgen
  • A. Teymourian
  • D. Thers
  • A. Tiseni
  • G. Trinchero
  • O. Vitells
  • H. Wang
  • M. Weber
  • C. Weinheimer
Publication date 11-2014
Journal Journal of Instrumentation
Article number P11006
Volume | Issue number 9 | 11
Organisations
  • Faculty of Science (FNWI) - Institute of Physics (IoP)
  • Faculty of Science (FNWI)
  • Faculty of Science (FNWI) - Institute of Physics (IoP) - Institute for High Energy Physics (IHEF)
  • Faculty of Science (FNWI) - Institute of Physics (IoP) - Institute for Theoretical Physics Amsterdam (ITFA)
Abstract

XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of 2·10-47 c 2 for WIMP masses around 50 GeV2, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of ∼ 10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons (>99.5%) and showers of secondary particles from muon interactions in the rock (>70%). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.

Document type Article
Language English
Published at https://doi.org/10.1088/1748-0221/9/11/P11006 https://doi.org/10.1088/1748-0221/9/11/P11006
Other links https://www.scopus.com/pages/publications/84914678803
Downloads
1406.2374 (Accepted author manuscript)
Permalink to this page
Back