The ATLAS Inner Detector commissioning and calibration
| Authors |
|
|---|---|
| Publication date | 2010 |
| Journal | European Physical Journal C |
| Volume | Issue number | 70 | 3 |
| Pages (from-to) | 787-821 |
| Organisations |
|
| Abstract |
The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1±0.9 μm and a relative momentum resolution σp/p = (4.83±0.16) × 10−4 GeV−1×pT have been measured for high momentum tracks.
|
| Document type | Article |
| Note | ATLAS Collaboration |
| Language | English |
| Published at | https://doi.org/10.1140/epjc/s10052-010-1366-7 |
| Downloads |
333190.pdf
(Final published version)
|
| Permalink to this page | |