Material radiopurity control in the XENONnT experiment

Open Access
Authors
Publication date 07-2022
Journal European Physical Journal C
Article number 599
Volume | Issue number 82 | 7
Number of pages 21
Organisations
  • Faculty of Science (FNWI) - Institute of Physics (IoP) - Institute for High Energy Physics (IHEF)
  • Faculty of Science (FNWI) - Institute of Physics (IoP)
Abstract

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and 222Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background (∼ 17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected 222Rn activity concentration in XENONnT is determined to be 4.2 (-0.7+0.5) μ Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.

Document type Article
Language English
Published at
Other links
Downloads
s10052-022-10345-6 (Final published version)
Permalink to this page
Back